Best Extrusion Plastometers- Melt Flow Index Testers

Best Extrusion Plastometers- Melt Flow Index Testers

Purpose of Melt Flow Index Test

Melt Flow Index Test is a very simple method that helps to characterize the flow properties of the melted plastics. This test method is widely used for the quality assurance purposes and raw material resting. This test can be performed using high-quality of Melt Flow Index Testers. The demand of the extrusion plastometers such as Melt Flow Index Tester varies as per the requirement arises for different applications in various plastic industries.

Presto Stantest, one of the renowned manufacturers of testing machines, designs, and manufactures high quality of Melt Flow Index Tester as per various standards that are introduced by different standardization authorities such as ASTM D1238 – 13, ASTM D2839 – 10, IS 2530 (1963), IS 10810- 1984 (Part 23), IS 2267 – 1995, JIS K 7210.

  • ASTM D1238 – 13: Standard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plastometer
  • ASTM D2839 – 10: Standard Test method for using Melt Index Strand for Determining Density of Polyethylene
  • IS 2530 (1963): Standard procedure to test polyethylene molding materials and polyethylene compounds
  • IS 10810- 1984 (Part 23): Methods to test cables: Melt Flow Index
  • IS 2267 – 1995: Specifications for Polystyrene Moulding and Extrusion Materials

Technical Specification of the Instrument As per the Standards

  • Temperature Range : Ambient to 400ºC.
  • Sample cutting : Manual & Automatic.
  • Diameter of heater tube cavity : 2.095mm±0.005mm,
  • Dimensions of piston head : 47 mm diameter x 6.35 mm length
  • Weights : 2 kg, 2.16kg, 3.8kg, 5kg.
  • Paint : Powder coated.
  • Power : 230 Volts, 50 Hz, single phase
  • Timer : Pre-set cyclic timer with settings1 to 999s
 

melt flow parts

SET Standardized Time & Temperature of the Machine for different Products

Most thermoplastic materials do not require conditioning prior to testing. However, materials which contain volatile components, are chemically reactive, or have other special characteristics, may require appropriate conditioning. The moisture content in the test specimen not only affects the reproducibility of flow rate measurement but may also cause accelerated degradation of the material at the temperature used in testing.

If conditioning is necessary, condition the samples under standard laboratory conditions of 27 +/- 2ºC temperature and 65 +/- 5% RH, or as specified in the applicable material specifications.

As per the Standard ASTM 1238, the test conditions can be selected on the basis of the following table:

The selection of the test temperature and test load is done in accordance with the applicable material specification. The test condition selected shall be such that the flow rate of the material under test falls between 0.15 to 50gms in 9/10 minutes.

Test ConditionTest Temperature (deg C)Test LoadRecommended for (Kg)
125/0.3251250.325Polyethylene
125/2.161252.16Polyethylene
150/2.161502.16Poly-vinyl acetal
190/0.3251900.325Cellulose esters, Polyethylene
190/1.051901.05Acetals (copolymer & homopolymer)
190/2.161902.16Acetals (copolymer & homopolymer), cellulose esters, polyethylene
190/5.01905.0Polystyrene
200/5.02005.0Acrylonitrile-butadiene-styrene, polystyrene
230/1.22301.2Acrylics
230/3.82303.8Acrylonitrile/butadiene/styrene/polycarbonate blends.
217.5/2.16217.52.16Ethylene-chlorotrifluoroethylene copolymer
297/5.02975.0Ethylene-tetrafluoroethylene copolymer
275/0.3252750.325Nylon
372/2.163722.16Perfluoro (ethylene-propylene) Copolymer
372/5.03725.0Perfluoroalkoxyalkane
125/2.161252.16Polycaprolactone
265/12.526512.5Polychlorotrifluorethylene
300/1.23001.2Polycarbonate
265/12.626512.6Polymonochloro trifluoroe thylene
230/2.162302.16Polypropylene
250/2.162502.16Polyterephthalate
230/21.623021.6Poly(vinylidene fluoride)
315/5.03155.0Poly (phenylene sulfide)
220/1022010Styrene acrylonitrile
190/2.161902.16Styrenic Thermoplastic Elastomer
190/2.161902.16Thermoplastic Elastomer-Ether-Ester
230/2.162302.16Thermoplastic elastomers (TEO)
230/21.623021.6Vinylidene fluoride copolymers

 

Recent News

blog img

Catalogue 2023

Get information about new product launches, research, innovation and endeavors at Presto.

download Free Copy

Need more information

Connect with us for your business enquiries. Generally we respond within one or two working days.

send enquiries

Contact Us

Get a Quote